Online Shopping Mall - Macedonia, Kosovo and Albania

AF26-30-00-11, ABB Contactor 26a DC

  • 4 In Stock

  • 0 Review(s)

Price :

41.74€

Product SKU: 36279

Product Net Width: 45mmproduct Net Depth/Length: 86MMProduct Net Height: 86mmnumber of Main Contacts No: 3Number of Main Contacts NC: 0number of Auxiliary Contacts No0standsiC/EN 60947 947-4-1, UL 60947-4 -1, CSA C22.2 No. 60947-4-1rated Operational Voltage: Main Circuit 690vrated Frequency (F): Control Circuit 50 /60 Hz Main Circuit 50 /60 Hzrated Operational Current AC-1 (IE) :( 690 V) 40 ) 60 c 40 a (690 V) 70 c 32 arated operational current AC-3 (IE): 415 V) 60 c 26 A (440 V) 60 c 26 A (500 V) 60 V c 23 a (690 V) 60 c 17 A (380 /400 V) 60 c 26 a (220 /230 /240 V) 60 c 26 arated operational current AC-3E (IE): . 26 A (220 /230 /240 V) 60 C 26 Arated Operational Power AC-3 (PE): 400 V) 11 kW (415 V) 11 kW (440 V) 15 kW (500 V) 15 kW (690 V) 15 kW (380 /400 V) 11 kW (220 /230 /240 V) 6.5 kwrated operational Power AC-3E (PE) :( 415 V) 11 kW (440 V) 15 kW (500 V) 15 kW ( 690 V) 15 kW (380 /400 V) 11 kW (220 /230 /240 V) 6.5 kwrated short-time with current Low Voltage (ICW): at 40 c ambient temp, in free air, from a color state 10 s 350 a at 40 c ambient temp, in free air, from a cold state 15 min 50 a at 40 c ambient temp, in free air, from a cold state 1 min 150 a at 40 c ambient Temp, in Free Air, From A Cold State 1 S 700 A AT 40 C Ambient Temp, In Free Air, From A Cold State 30 S 225 Amaximum Breaking Capacity: COS Phi = 0.45 (cos Phi = 0.35 for ie 100 a) at 440 v 500 a cos phi = 0.45 (cos phi = 0.35 for ie 100 a) at 690 V 200 Amaximum Electrical Switching Frequency: (AC-1) 600 Cycles Per Hour (AC-2 / AC-4 ) 150 Cycles Per Hour (AC-3) 1200 Cycles Per Hourrated Operational Current DC-1 (IE) :( 110 V) 2 Poles in Series, 40 C 45 A (110 V) 2 Poles in Series, 60 C 40 A (110 V) 2 Poles in Series, 70 C 32 A (110 V) 3 Poles in Series, 40 C 45 A (110 V) 3 Poles in Series, 60 C 40 A (110 V) 3 Poles in Series, 70 C 32 A (220 V) 3 Poles in Series, 40 C 45 A (220 V) 3 Poles in Series, 60 C 40 A (220 V) 3 Poles in Series, 70 c 32 A (72 V) 1-Pole, 40 C 45 A (72 V) 1-Pole, 60 C 40 A (72 V) 1-Pole, 70 C 32 A (72 V) 2 Poles in Series, 40 C 45 A (72 V) 2 Poles in Series, 60 C 40 A (72 V) 2 Poles in Series, 70 C 32 A (72 V) 3 Poles in Series, 40 C 45 A (72 V) 3 Poles in Series, 60 C 40 A (72 V) 3 Poles in Series, 70 C 32 Arated Operational Current DC-3 (IE) :( 110 V) 2 Poles in Series, 40 C 45 A (110 V) 2 Poles in Series, 60 C 40 A (110 V) 2 Poles in Series, 70 C 32 A (110 V) 3 Poles In series, 40 c 45 a (110 V) 3 Poles in Series, 60 C 40 A (110 V) 3 Poles in Series, 70 C 32 A (220 V) 3 Poles in Series, 40 & Deg ; C 45 A (220 V) 3 Poles in Series, 60 C 40 A (220 V) 3 Poles in Series, 70 C 32 A (72 V) 1-Pole, 40 C 45 A (72 V) 1-Pole, 60 c 40 A (72 V) 1-Pole, 70 C 32 A (72 V) 2 Poles in Series, 40 C 45 A (72 V) 2 Poles in Series, 60 c 40 A (72 V) 2 Poles in Series, 70 C 32 A (72 V) 3 Poles in Series, 40 C 45 A (72 V) 3 Poles in Series, 60 C 40 A (72 V) 3 Poles in Series, 70 C 32 Arated Operational Current DC-5 (IE): 110 V) 2 Poles in Series, 40 C 45 A (110 V) 2 Poles in Series, 60 & Deg ; C 40 A (110 V) 2 Poles in Series, 70 C 32 A (110 V) 3 Poles in Series, 40 C 45 A (110 V) 3 Poles in Series, 60 C 40 A ( 110 V) 3 Poles in Series, 70 C 32 A (220 V) 3 Poles in Series, 40 C 20 A (220 V) 3 Poles in Series, 60 C 20 A (220 V) 3 Poles In series, 70 c 20 a (72 V) 1-Pole, 40 c 20 a (72 V) 1-Pole, 60 c 20 A (72 V) 1-Pole, 70 c 20 A (72 V) 2 Poles in Series, 40 C 45 A (72 V) 2 Poles in Series, 60 C 40 A (72 V) 2 Poles in Series, 70 C 32 A (72 V) 3 Poles in Series, 40 C 45 A (72 V) 3 Poles in Series, 60 C 40 A (72 V) 3 Poles in Series, 70 C 32 Arated Insulation Voltage (UI): ACC. to IEC 60947-4-1 690 V ACC. To UL/CSA 600 Vrated Impulse with Voltage (UIMP): 6 kvmaximum Mechanical Switching Frequency: 3600 Cycles Per Hourrated Control Circuit Voltage (UC): 50 Hz 24 ... 60 Hz 24 ... 60 V DC Operation 20. .. 60 VOPERATE TIME: BETWEEN COIL DE-ENERGERATION AND NC CONTACT CLOSING 13 ... 98 MS Between Coil De-ENERGERATION AND NO CONTACT OPENING 11 ... 95 MS Between Coil Energization and NC Contact Opening 38 ... COIL ENERGERATION AND NO CONTACT CLOSING 40 ... 95 msconnecting capacity main circuit: Flexible with ferrule 1/2x 1.5 ... 10 mm Flexible with insulated ferrule 1x 1.5 ... 10 mm Flexible with insulated ferrule 2x 1.5 ... 4 mm Rigid Solid 1/2x 2.5 ... 4 mm Rigid Stranded 1/2x 2.5 ... 10 mm Connecting Capacity Control Circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mm Flexible with insulated ferrule 1x 0.75 ... 2.5 mm Flexible with insulated ferrule 2x 0.75 ... 1.5 mm Rigid Solid 1/2x 1 ... 2.5 mm Rigid stranded 1/2x 1 ... 2.5 mm degree of ProtectionACC. to IEC 60529, IEC 60947-1, EN 60529 COIL TERMINALS IP20 ACC. to IEC 60529, IEC 60947-1, EN 60529 MAIN TERMINALS IP20

Ratings & Reviews

0.0

No Review Found.


To Review


To Comment